YH-830 Bi-Level PAP Ventilator

The YH-830 Bi-level ventilator device is indicated for treatment of sleep apnea hypopnea syndrome in patients weighing more than 66 lb (30kg). This ventilator is intended both for home use and hospital use. The water tank is intended for single patient use in the home environment and re-use in a hospital/institutional environment.

YH-830 Ventilator Details
Mode: CPAP, S, T, ST, VGPS
Pressure: 4-30 cm H2O
Trigger adjustment
Cycle adjustment
Sloop adjustment
Noise less than 32 dB(A) with YF-01 mask and humidifier and SD card

Flow range: 0.5~5 L/min
Oxygen concentration: 95.5%~87%
Max outlet pressure: 40~70kPa
Sound level: Front side 48dB(A)(overage),whole unit 52dB(A)
Input power: 400VA
Weight: 15.5kg(34.1 lbs)
Min operating time: 30 minutes

Category:

Description

The YH-830 Bi-level ventilator device is indicated for treatment of sleep apnea hypopnea syndrome in patients weighing more than 66 lb (30kg). This ventilator is intended both for home use and hospital use. The water tank is intended for single patient use in the home environment and re-use in a hospital/institutional environment.

YH-830 Ventilator Details
Mode: CPAP, S, T, ST, VGPS
Pressure: 4-30 cm H2O
Trigger adjustment
Cycle adjustment
Sloop adjustment
Noise less than 32 dB(A) with YF-01 mask and humidifier and SD card

Flow range: 0.5~5 L/min
Oxygen concentration: 95.5%~87%
Max outlet pressure: 40~70kPa
Sound level: Front side 48dB(A)(overage),whole unit 52dB(A)
Input power: 400VA
Weight: 15.5kg(34.1 lbs)
Min operating time: 30 minutes

 

Technical parameters of YH-830 mobile bi-level PAP device

  1. Scope of application:
    For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive ventilation in a hospital or home.
    2 . the main function:
    1、Different treatment options can be provided according to patients’ needs, from CPAP to S, T, S / T, VGPS five modes。
  2. Adjustable trigger sensitivity.
    3.Prompt function.
  3. Record function (SD card).
  4. Maximum leak compensation function. 60L/min
  5. the key technical parameters:
  6. Working mode: CPAP, S, T, ST, VGPS.
  7. Ventilation parameters:
    2.1 Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval)
    2.2 Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval)
    2.3 Treatment pressure: 4-20 cmH2O (in CPAP mode, 0.5 cmH2O interval)
    2.4 Delayed boost: 0-45 minutes (interval of 5 minutes)
    2.5 Breathing frequency: 5-50 times / minute (interval 1 time / minute)
    2.6 Breathing ratio: 10-70% (interval of 1%)
    2.7 Rise time: 1-5 steps (1 step interval, 1 step rises fastest, 5 steps rises most slowly)
    2.8 Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest)
    2.9 Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the slowest)
    2.10 Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml)、
    3.VGPS(same with AVAPS,can set Target tidal volume)mode:
    3.1 Maximum IPAP value adjustable range: 4-30 cmH2O
    3.2 Adjustable range of minimum IPAP value: 4-30 cmH2O
    3.3 EPAP value adjustable range: 4-30 cmH2O
    3.4 Target Tidal Volume: 50-1500ml
  8. Display range of monitoring setting parameters:
    4.1 Respiratory waveform can be displayed;
    4.2 Current mode: CPAP, S, T, ST, VGPS
    4.3 Inspiratory pressure: 4-30 cmH2O
    4.4 Expiratory pressure: 4-30 cmH2O
    4.5 Breathing frequency: 5-50 times / minute
    4.6 Breathing ratio: 10-70%
    4.7 Air leakage: 20-99.9lpm
    4.8 Tidal volume: 50-1500ml
    4.9 minute ventilation: 0-50lpm
    4.10 Blood oxygen saturation: 70-100%
    4.11 Pulse rate: 25-250bpm
    4.12 Delay boost: 0-45 minutes
  9. Alarm items:
    5.1 High pressure sound prompt: Turn on / off sound prompt
    5.2 Low minute ventilation sound prompt: Turn on / off sound prompt, can be set to 1-10L (interval 1L)
    5.3 Air leakage sound prompt: on / off
    5.4 Power off sound prompt: on / off
    5.5 Choking voice prompt: On / off, choking time can be set to 10-40 seconds (interval of 5 seconds)
    5.6 Low Tidal Volume Sound Prompt: On / Off, Set Tidal Volume Value Range 50-500ml ((Interval 50ml))